No.
Item
Range
Default
Description
Please refer to Table 11 for
details.
2
Output Type
(0-1)
0
0: Normally Open
1: Normally Close
Auxiliary Output 7
1
Contents Setting
(0-139)
0
Not Used;
Please refer to Table 11 for
details.
2
Output Type
(0-1)
0
0: Normally Open
1: Normally Close
Auxiliary Output 8
1
Contents Setting
(0-139)
0
Not Used;
Please refer to Table 11 for
details.
2
Output Type
(0-1)
0
0: Normally Open
1: Normally Close
Auxiliary Output 9
1
Contents Setting
(0-139)
0
Not Used;
Please refer to Table 11 for
details.
2
Output Type
(0-1)
0
0: Normally Open
1: Normally Close
Auxiliary Output 10
1
Contents Setting
(0-139)
0
Not Used;
Please refer to Table 11 for
details.
2
Output Type
(0-1)
0
0: Normally Open
1: Normally Close
Alternate Configuration Setting
Alternate Configuration 1
1
Enable Choose
(0-1)
0
0: Disable 1: Enable
2
Engine Rated Speed
(0-6000) r/min
2200
When this is enabled, if
input is configured to “Alt
Config. 1 Active”, and if
input is active, speed shall
be adjusted according to
alternate
configuration
settings after load.
3
Engine Idle Speed
(0-100.0)%
64.0
4
Air Com. Onload Speed
(0-100.0)%
64.0
5
Engine Unload Speed
(0-100.0)%
70.0
6
Air Com. Target Pressure
(0-30000)kPa
700
7
Air Com. Unload Act Pressure
(0-30000)kPa
600
8
Onload Output Selection
(0-3)
1
0: Load Control;
1: Load Control 1
2: Load Control 2
3: Load Control 3
9
Overload Maint. Speed
(0-100.0)%
70.0
Alt Config. 1 Rated Speed
percentage;