Page 58
EN
6. Adjustment
The Mobil PGA 3 (or laptop) associated with
the VARIOLUB monitoring system is required
to achieve exact adjustment of the low rate.
This unit is connected to the respective pulse
measuring unit (IPM-12) that monitors the
low meter to be adjusted.
A comparison of actual and speciied values
should be made with the help of the pulse
measuring unit before starting with the adjust-
ment of the low meter.
For the exact procedure consult the operating
instructions ”VARIOLUB monitoring system for
low meter lubrication systems”, order No.
951-130-310
(PGA 3).
The following data apply to the basic settings:
SMD 1B .............. 1 pulse = 2.6 ml
SMD 2 ................ 1 pulse = 9.3 ml
SMD 3 ................ 1 pulse = 39 ml
Connecting the PGA 3 Programming and
Display Unit
•
Connect the Mobile PGA 3 (
1
) to the pulse
measuring unit (IPM-12) (
2
)
•
Insert an allen key (WAF 4) (
3
) in the
throttle screw (
4
) of the low meter to be
adjusted
•
Using the pulse measuring unit (IPM12),
select the measuring point of the low
meter (
4
) to be adjusted
See 951-130-310 (PGA 3), Chapter 5.1.2
”Comparison of IPM-12 speciied and
actual values”
Reading out the actual and speciied values
• Read out the speciied and actual values
with the Mobile PGA 3 (Programming and
Display Unit)
See 951-130-310 (PGA 3), Chapter 5.3
”Reading out the speciied and actual values”
Adjusting the throttle screw
•
Change the setting of the throttle screw
(
4
) with an allen key (
3
) until the actual
value matches the speciied value on the
display of the Mobile PGA 3 (
1
)
The low rate drops when the throttle
screw is turned clockwise and rises when
turned counterclockwise.
6.1 Adjustment of the SMD low meter
Fig. 11 Adjustment of the SMD flow meter
6. Adjustment