Working with the Web Pages
Page 79
Image Quality not OK: Alarm output = true
The red circle around the Focus dial in the figure above indicates that the alarm is raised by the
Focus measurement. The Exposure dial has no red circle, although the pointer is in the
Hysteresis area. This shows that Exposure was correct before and that this measurement in itself
is not the cause of the alarm.
Note:
In addition to the visual indications on the web pages, alarms can also be read from the
C-60 E-MC 's internal Management Information Base (MIB) using appropriate software, or
through
Siqura‟s Open Streaming Architecture (OSA) –
that is, the “PTZ Camera and Codec
Programming Interface” (API)
. The C-60 E-MC includes SNMP support for its image quality
monitor and tampering detection. A trap is sent when bad image quality or camera tampering
has been detected and another one when the situation returns to normal. This support requires
a new SNMP MIB, the OPTC-VCA-MIB, which can be downloaded at www.siqura.com.