Siqura C-60 E-MC
Page 4
Optical Safety (C-60 E-MC /SFP)
This optical equipment contains Class 1M lasers or LEDs and has been designed and tested to
meet
IEC 60825-1:1993+A1+A2
and
IEC 60825-2:2004 safety class 1M
requirements.
Warning:
Optical equipment presents potential hazards to testing and servicing personnel, owing
to high levels of optical radiation.
When using magnifying optical instruments, avoid looking directly into the output of an
operating transmitter or into the end of a fiber connected to an operating transmitter, or there
will be a risk of permanent eye damage. Precautions should be taken to prevent exposure to
optical radiation when the unit is removed from its enclosure or when the fiber is disconnected
from the unit. The optical radiation is invisible to the eye.
Use of controls or adjustments or procedures other than those specified herein may result in
hazardous radiation exposure.
The installer is responsible for ensuring that the label depicted below (background: yellow;
border and text: black) is present in the restricted locations where this equipment is installed.
EMC
The equipment has been tested and found to meet the CE-regulations relating to EMC, and
complies with the limits for a Class B device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against interference to radio communications in
any installation. The equipment generates, uses, and can radiate radio frequency energy;
improper use or special circumstances may cause interference to other equipment or a
performance decrease due to interference radiated by other equipment. In such cases, the user
will have to take appropriate measures to reduce such interactions between this and other
equipment.
Any interruption of the shielding inside or outside the equipment could make the equipment
more prone to fail EMC requirements.
Non-video signal lines must use appropriate shielded Cat 5 cabling (S-FTP), or at least an
equivalent. Ensure that
all
electrically connected components are carefully earthed and
protected against surges (high voltage transients caused by switching or lightning).
ESD
Electrostatic discharge (ESD) can damage or destroy electronic components.
Proper precautions
should be taken against ESD when opening the equipment.
Care and Maintenance
The encoder will normally need no maintenance. In order to keep the module operating reliably,
please observe the following.
Prevent dust from collecting on the module.
Do not expose the equipment to moisture.
Keep the module within the appropriate temperature range as described in the Technical
Specifications section.
Summary of Contents for C-60 E-MC
Page 1: ...Siqura C 60 E MC Firmware version 3 12 H 264 Multicodec Video Server User Manual M C...
Page 6: ......
Page 8: ......
Page 12: ...Siqura C 60 E MC Page 6 2 2 Declaration of Conformity...
Page 16: ......
Page 20: ......
Page 30: ...Siqura C 60 E MC Page 24 C 60 E MC login page Connect box...
Page 134: ......
Page 142: ......