Siqura C-60 E-MC
Page 104
10.7
Data RS-232
Data RS-232 page
RS-232 configuration
Configuration of the RS-232 interface is almost identical to configuring RS-422/485 settings
(with the exception that there is no line termination or biasing with RS-232). For a detailed
description, refer to the section covering RS-422/485.
To set up an RS-232 data link
1. Assign a destination IP address (a specific host or a multicast group) to a serial transmitter
output stream (1, 2 or 3).
2. Assign a suitable destination port (even number) to the transmitter output stream.
3. Enable the stream.
4. Save the settings.
5. At the receiver end, fill in the source IP address.
6. At the receiver end, fill in the local port number (the same as the destination in the
transmitter).
7. Enable reception.
8. Save the settings.