Working with the Web Pages
Page 115
10.11.3
MX tab
Device Management page, MX tab
MX/IP
MX/IP is a UDP protocol used to communicate with Siqura equipment over a network connection.
The Siqura Software Suite applications use the MX/IP protocol to access, configure, and control
Siqura network devices.
MX/IP
Enable MX
In addition to the proprietary MX/IP protocol, a C-60 E-MC can be accessed,
configured and managed using a variety of open standards. Therefore, you can
disable the MX protocol. Be aware that doing so will prevent you from upgrading
the C-60 E-MC firmware through the MX Firmware Upgrade Tool application.
MX Notifications
IP address
With 255.255.255.255 as the IP address for the manager, the MX notifications
would be broadcast over the subnet.
Port
Generally, the MX notifications port must not be modified.
Unsolicited notifications
interval
Sends the module status as MX notification at the specified interval to be picked
up by a management program.
Retransmission count
If desired, notifications can be retransmitted. With a retransmission count value
of 2, the actual number of transmissions equals 3 (including the original
transmission).
Retransmission interval
Sets the frequency of retransmissions.