CR40/42/50 MKII Installation manual
Chapter 9
147
9.9.5 Grounding wire
Connect grounding wire from one of the bolts used for mounting the scanner unit
to ship’s hull. The crimp terminal and grounding wire are not included with the
radar equipment.
Radome
Open scanner
Mount base
Radome (bottom)
Chassis
To ship’s hull
Crimp terminal
Grounding wire