CR40/42/50 MKII ECHO and SPECIAL menus
Chapter 8
106
Setup for Depth:
Scale for depth: 0
→
→
→
→
100 m
Depth min. alarm: 0010 m OFF
Depth max. alarm: 0100 m OFF
Color for depth:
Scale for temperature: 0
→
→
→
→
20 °C
Color for temperature:
Interval of screen: TIME
Time interval: 5 MIN.
Go to the function you wish to change
0-9
Key in new figure, or…
+/-
change setting
ENT
Confirm entry
Scale for depth
– there are six depth scales to choose from, ranging
from 0-10m to 0-3000m. Toggle with +/- keys.
Alarm
– figures for minimum and maximum depths can be inserted,
and alarms can be activated/deactivated.
Color
– for depth and temperature can be changed. Toggle between
available colors by means of the +/- keys.
Scale for temperature
– can be set to 0-10°, 0-20°, 0-30°, 10-20° and
–10 to 10 °C. The source for temperature is selected in NMEA setup 1
or 2.
Interval of screen
– Interval for updating of screen can be related to
TIME
or
DISTANCE.
TIME
interval can be set in 6 intervals from 5 minutes to 3 hours
(+ freeze) for refreshing of the screen.
DISTANCE
can be set in 7 intervals ranging from 0.5 nm to 90 nm in
order to adjust to the boat’s speed, and you can freeze the reading.