30
SafeLINC Fire Panel Internet Interface (FPII) Boot
Procedure in Progress:
SafeLINC FPII System Firmware Revision 2.00.19
SafeLINC FPII Static IP Address...: 10.26.3.194
SafeLINC FPII Subnet Mask.........: 255.255.0.0
SafeLINC FPII Default Gateway.....: 10.26.1.254
HARDWARE PARAMETERS:
SafeLINC FPII MAC Address........:
00:08:BD:FF:FF:25
SafeLINC FPII NVRAM Data Size....: 15423 bytes
Summary of Configurables
========================
SafeLINC FPII MAC Address.........: 00:08:BD:FF:FF:1C (Not user configurable)
SafeLINC FPII Static IP Address...: 10.26.3.194
SafeLINC FPII Subnet Mask.........: 255.255.0.0
SafeLINC FPII Default Gateway.....: 10.26.1.254
SafeLINC FPII Admin Password......: password
SafeLINC FPII 'User 1' Username...: SafeLINC_Customer
SafeLINC FPII 'User 1' Password...: password
SafeLINC FPII Boot-up delay.......: 5 seconds
6.
After you type <S> and press [ENTER], the screen displays the following:
This information stays on-screen for the duration of the Boot-up Delay period. During this period,
you may press any key to further modify the settings. If you don’t press a key, the system will
continue to boot.
7.
When you have verified that the settings are correct, type <B> and press [ENTER] to store the
configuration into non-volatile memory and reboot the SafeLINC FPII. If you didn’t make
any changes, type <Q> and press [ENTER] to quit without saving any modifications and the
SafeLINC FPII reboots. (The SafeLINC FPII takes several minutes to boot into operation.)
When normal boot-up of the SafeLINC FPII occurs, the following is displayed:
Notes:
•
The SafeLINC FPII automatically reboots after 10 minutes of detected non-activity on
the boot prompt. Any changes that you made, but did not save, are lost when the
timeout occurs. The SafeLINC FPII attempts to boot into successful operation only
when you specify and save all parameters.
•
You must complete all parameters before the SafeLINC FPII attempts a complete
boot procedure. If parameters are missing, then the SafeLINC FPII automatically
goes to the boot prompt so that you can finalize the required configuration
parameters.
The SafeLINC FPII is operational once you observe the message:
***********************************************************************
The SafeLINC Fire Panel Internet Interface (FPII) is now ready for use.
***********************************************************************
You may access the SafeLINC FPII using the assigned DNS name provided
by your MIS/IT department. Refer to your MIS/IT worksheet as needed.
Using the Boot Menu,
Continued
Entering Data from
the MIS/IT
Configuration
Worksheet