66
PAR.
NO.
Description
Range
U/M
Step
Default
30
Relay 1 function
0 = not used
1 = solar pump
2 = direct zone 1
3 = N.O. boiler ON/OFF status output
4 = N.C. boiler ON/OFF status output
5 = N.O. alarm output
6 = N.C. alarm output
7 = direct zone 2
8 = mix valve (position A)
9 = mix valve (position B)
10 = remote ignition transformer
11 = mix zone pump for hybrid kit
12 = supplementary source – heat pump
13 = supplementary source – pellet boiler
14 = supplementary source – fireplace or heat pump with
photovoltaic consent
15 = semi-automatic filling
16 = DHW recirculation pump
17 = command
18 = function
-
-
0
31
Relay 2 function
0 = not used
1 = solar pump
2 = direct zone 1
3 = N.O. boiler ON/OFF status output
4 = N.C. boiler ON/OFF status output
5 = N.O. alarm output
6 = N.C. alarm output
7 = direct zone 2
8 = mix valve (position A)
9 = mix valve (position B)
10 = remote ignition transformer
11 = mix zone pump for hybrid kit
12 = supplementary source – heat pump
13 = supplementary source – pellet boiler
14 = supplementary source – fireplace or heat pump with
photovoltaic consent
15 = semi-automatic filling
16 = DHW recirculation pump
17 = command
18 = function
-
-
0
32
Relay 3 function
0 = not used
1 = solar pump
2 = direct zone 1
3 = N.O. boiler ON/OFF status output
4 = N.C. boiler ON/OFF status output
5 = N.O. alarm output
6 = N.C. alarm output
7 = direct zone 2
8 = mix valve (position A)
9 = mix valve (position B)
10 = remote ignition transformer
11 = mix zone pump for hybrid kit
12 = supplementary source – heat pump
13 = supplementary source – pellet boiler
14 = supplementary source – fireplace or heat pump with
photovoltaic consent
15 = semi-automatic filling
16 = DHW recirculation pump
17 = command
18 = function
-
-
0
33
Relay 4 function
0 = not used
1 = solar pump
2 = direct zone 1
3 = N.O. boiler ON/OFF status output
4 = N.C. boiler ON/OFF status output
5 = N.O. alarm output
6 = N.C. alarm output
7 = direct zone 2
8 = mix valve (position A)
9 = mix valve (position B)
10 = not used
11 = mix zone pump for hybrid kit
12 = supplementary source – heat pump
13 = supplementary source – pellet boiler
14 = supplementary source – fireplace or heat pump with
photovoltaic consent
15 = semi-automatic filling
16 = DHW recirculation pump
17 = command
18 = function
-
-
0