52
– press the
click
encoder to confirm the highlighted “Row” and
access the modifiable area
Room 1 - Settings
Function Mode
AUTO
Set AUTO comfort
20.5°C
Set AUTO reduced
17.0°C
Set MAN
19.2°C
Program. Time
[...]
Fig. 70
– turn the
encoder to modify the “Data/value” in the per-
mitted field (e.g. OFF - ECO - MAN - AUTO)
– press the
click
encoder to confirm any modifications made
and go back to the row
“Function mode”
(Function Mode).
m
CAUTION
The settings described above must be done for both
zones.
m
CAUTION
For information on boiler time programming, see “
7.3.2
Fault warnings
If a fault occurs, the screen
“Anomaly in progress”
(Fault in pro-
gress) will appear in place of the “main screen”. For the main
fault codes, a brief description and suggestions for the user
are displayed, based on the seriousness and the frequency with
which the fault reappears.
Fault in progress
ALL 05 - Flow sensor fault
Esc
Fault in progress
Reset
ALL 06 - No flame detection
Fig. 71
The fault may be
transient
(volatile) or it may cause an appliance
block
.
To restore normal operating conditions:
– if the fault is transient, eliminate the cause of the fault
– if the fault causes a block, eliminate the cause of the fault and
then press the
“RESET”
(Reset) button; press the
en-
coder to confirm.
Fault in progress
ALL 02 - Low system water pressure
Fill
Fault in progress
Confirm operation
Confirm
Fig. 72
A list of possible faults is given under "
7.3.3
Time Programming
The
control panel
allows up to a maximum of four daily time
bands to be managed for the domestic hot water function and the
heating function described below.
During the programmed time band, the boiler works in COMFORT
heating mode, while outside the programmed time band it works
in REDUCED heating mode:
– press the encoder
click
to confirm
“Program. Time”
(Pro-
gram. Time) and go into the modifiable area
Confirm
Heating Time Program
0246
81
01 21 41 61 82 02 22 4
[1] 06:00 - 08:00
[2] 11:00 - 13:00
[3] -
[4] 18:00 - 23:00
Monday
Day/s
Fig. 73
– turn the
encoder to select the “Single days” or the
“Group of days”
– press the
click
encoder to confirm the required selection and
access the first “Adjustable time”
[1]
Heating Time Program
0246
81
01 21 41 61 82 02 22 4
[1] 06:00 - 08:00
[2] 11:00 - 13:00
[3] -
[4] 18:00 - 23:00
Monday
Day/s
Confirm
Fig. 74
– turn the
encoder to modify the “Data/value” on the ba-
sis of the required time
– press the
click
encoder to confirm the modification and move
to the next “Data/value”
Heating Time Program
0246
81
01 21 41 61 82 02 22 4
[1] 06:00 - 08:00
[2] 11:00 - 13:00
[3] -
[4] 18:00 - 23:00
Monday
Day/s
Confirm
Fig. 75
Summary of Contents for 8115101
Page 6: ...6 ...