12
1.4
Fault warnings
If a fault occurs, the screen
“Anomaly in progress”
(Fault in pro-
gress) will appear in place of the “main screen”. For the main
fault codes, a brief description and suggestions for the user
are displayed, based on the seriousness and the frequency with
which the fault reappears.
Fault in progress
ALL 05 - Flow sensor fault
Esc
Fault in progress
Reset
ALL 06 - No flame detection
Fig. 15
The fault may be
transient
(volatile) or it may cause an appliance
block
.
To restore normal operating conditions:
– if the fault is transient, eliminate the cause of the fault
– if the fault causes a block, eliminate the cause of the fault and
then press the
“RESET”
(Reset) button; press the
en-
coder to confirm.
Fault in progress
ALL 02 - Low system water pressure
Fill
Fault in progress
Confirm operation
Confirm
Fig. 16
m
CAUTION
For a full list of faults, see "
1.5
Time Programming
The
control panel
allows up to a maximum of four daily time
bands to be managed for the domestic hot water function and the
heating function described below.
During the programmed time band, the boiler works in COMFORT
heating mode, while outside the programmed time band it works
in REDUCED heating mode:
– press the encoder
click
to confirm
“Program. Time”
(Pro-
gram. Time) and go into the modifiable area
Confirm
Heating Time Program
0246
81
01 21 41 61 82 02 22 4
[1] 06:00 - 08:00
[2] 11:00 - 13:00
[3] -
[4] 18:00 - 23:00
Monday
Day/s
Fig. 17
– turn the
encoder to select the “Single days” or the
“Group of days”
– press the
click
encoder to confirm the required selection and
access the first “Adjustable time”
[1]
Heating Time Program
0246
81
01 21 41 61 82 02 22 4
[1] 06:00 - 08:00
[2] 11:00 - 13:00
[3] -
[4] 18:00 - 23:00
Monday
Day/s
Confirm
Fig. 18
– turn the
encoder to modify the “Data/value” on the ba-
sis of the required time
– press the
click
encoder to confirm the modification and move
to the next “Data/value”
Heating Time Program
0246
81
01 21 41 61 82 02 22 4
[1] 06:00 - 08:00
[2] 11:00 - 13:00
[3] -
[4] 18:00 - 23:00
Monday
Day/s
Confirm
Fig. 19
– continue in this way until all the necessary modifications have
been made for each day of the week or group of days.
NOTE
: The user must work in a CIRCULAR manner, meaning AL-
WAYS MOVING FORWARDS, even if a mistake is made.
m
CAUTION
If NO time band is required, set the start and stop times
of that band to the same value (e.g. [3] 14:00-14:00).
– When all modifications have been made, turn the
en-
coder to select
“Confirm”
(Confirm) and press the
click
en-
coder to go back to “Single days” or “Groups of days”
– press the
“ESC”
button to go back to the “main screen”.
Menu
Mode
Zones
Mon 01.01.2018
10:30
Fig. 20
Summary of Contents for 8115101