51
– press the
click
encoder to confirm the highlighted “Row” and
access the modifiable area
Hot water
Function Mode
MAN
Hot water setting
45°C
Program. Time
[...]
Fig. 65
– turn the
encoder to modify the “Data/value” in the per-
mitted field (e.g. OFF - ECO - MAN - AUTO)
– press the
click
encoder to confirm any modifications made
and go back to the row
“Function mode”
(Function Mode).
m
CAUTION
For information on boiler time programming, see “
The characteristics of each operating mode available are de-
scribed below:
Function mode
Description
OFF
DHW (domestic hot water) request NOT
active
ECO
Instantaneous operation (factory setting)
MAN
DHW 3-star function ALWAYS active (with
PAR 37 = 1)
AUTO_ON
MAN mode operation when the time slot
has been activated
AUTO_OFF
ECO mode operation when the time slot
has been deactivated
7.3.1.2 DHW 3-star function
This function is included on boiler models with instantaneous hot
water function, with PAR 47 = 1 the function activates when MAN
or AUTO mode is set in the ON bands.
Moreover, this function:
– is activated if, during a domestic hot water (DHW) request, the
burner turns on for more than 5 seconds
– the function keeps the burner active (at minimum power) at the
end of the DHW request, depending on the temperature of the
primary heat exchanger
– the function has a maximum duration of 1 hour
– the total execution time is reloaded only if the 3-star function is
interrupted by a DHW request
– if the 3-star function is interrupted by a heat request from the
heating circuit, or by a request with higher priority, the function
will be deactivated.
m
CAUTION
When the "DHW 3-star" function is activated, it is rec-
ommended to set the "Hot water set" to a value below
45°C to prevent excessive temperatures when water
starts being drawn.
m
CAUTION
Setting of the remote control SIME HOME PLUS: to dis-
able the DHW 3-star function (enabling in ECO mode),
set the domestic hot water (DHW) function to AUTO
mode and disable the MON-SUN period for all time
bands.
7.3.1.3 Heating
– turn the
encoder to select
“Heating”
(Heating)
– press the
click
encoder to confirm
“Heating”
(Heating) and
open the submenu
“Zone”
(Zones)
Heating
Zone 1
[...]
Zone 2
[...]
Summer
Winter
Off
Hot water
MAN
40
°C
Heating
Esc
Fig. 66
– turn the
encoder to select the desired zone e.g. Zone 1
(Zone 1) or Zone 2 (Zone 2)
– press the
click
encoder to confirm the highlighted zone and
go to the row
Zone 1
Information
[...]
Settings
[...]
Config
[...]
Fig. 67
Turn the encoder
until selecting the desired function, e.g.
Settings
Zone 1
Information
[...]
Settings
[...]
Config
[...]
Fig. 68
– press the
click
encoder to confirm the selected submenu
and access the relevant data display
Room 1 - Settings
Function Mode
AUTO
Set AUTO comfort
20.5°C
Set AUTO reduced
17.0°C
Set MAN
19.2°C
Program. Time
[...]
Fig. 69