65
7.5
List of parameters
Parameter PAR 01 is factory set according to the table “A” below and automatically generates the settings for parameters PAR 05 and
PAR 09.
d
IT IS FORBIDDEN
Use settings other than those shown in table “A” as this could generate a serious boiler malfunction.
TABLE “A”
PAR.
NO.
Type of gas
METHANE
LPG
G20 - I2E
Boiler power (kW)
25
30
35
25
30
35
25
30
35
01
Index showing boiler power in kW and type of boiler
2
3
4
6
7
8
10
11
12
PAR.
NO.
Description
Range
U/M
Step
Default
02
Hydraulic configuration and system type
-
-
1
04
System connected to circuit 1
0 = high temperature
1 = low temperature
-
-
0
05
Water pressure switch TSP
0 = water pressure switch
1 = water pressure transducer (only
pressure displayed)
2 = transducer 0-4 bar
-
-
2
06
External sensor value correction
-5 .. +5
°C
1
5
07
Boiler and AUX anti-freeze threshold
0 .. +10
°C
1
3
08
External Sensor Antifreeze Threshold
-- = Disabled
-9 .. +5 .. [15 = disabled]
°C
1
7
09
Ignition fan speed
80 .. 160
RPMx25
1
128
10
Select heat pump or boiler switchover
-20 .. 30
°C -20
1
25
11
Boiler activation delay after heat pump activation
1 .. 60
Min
1
20
12
Minimum Heating Temperature Adjustment Zone 1
20 .. PAR 13
°C
1
20
13
Maximum Heating Temperature Adjustment Zone 1
PAR 12 .. 80
°C
1
80
14
Zone 1 heating climatic curve K
3 .. 40
-
1
20
15
Minimum Heating Temperature Adjustment Zone 2
20 .. PAR 16
°C
1
20
16
Maximum Heating Temperature Adjustment Zone 2
PAR 15 .. 80
°C
1
80
17
Zone 2 heating climatic curve K
3 .. 40
-
1
20
18
Heating Curve Incline
0 .. 80
TSP x 10.2
secs
1
20
19
Heating maximum Output (user)
0 .. 100
%
1
100
20
Minimum power heating/domestic hot water (premixed)
0 .. 100
%
1
0
21
Heating Post-Circulation Time
0 .. 99
TSP x 10
secs
1
3
22
Heating Pump Activation Delay
0 .. 60
sec.
1
0
23
Activation delay (AFCT)
0 .. 60
Min
1
3
24
Maximum domestic hot water temperature
35 .. 67
°C
1
60
25
Maximum power domestic hot water
0 .. 100
%
1
100
26
Configuring the DHW
0 = rapid
1 = hot water tank with thermostat
2 = hot water tank with sensor
-
-
-
27
DHW activation delay with solar power
0 .. 30
sec.
1
0
28
Anti-legionella Function (Only hot water tank)
-- = Disabled
50 .. 80
°C
1
49
29
Domestic Hot Water Modulation with Flow meter
0 = Disabled
1 = Enabled
-
-
0