GB
8
Problem
Possible cause
Solution
Router will not operate
No supply of power
Check that power is available at source
Brushes worn or sticking
Disconnect power, open Brush Access Covers (4) & (20) . and ensure brushes are
not damaged or heavily worn
Switch is faulty
Contact an authorised repair agent
Motor components faulty or short circuited
Contact an authorised repair agent
Router runs or cuts slowly
Blunt or damaged cutter
Re-sharpen or replace cutter
Variable Speed Dial (5) set low
Increase variable speed setting
Motor is overloaded
Reduce pushing force on router
Makes an unusual sound
Mechanical obstruction
Contact an authorised repair agent
Armature has shorted sections
Contact an authorised repair agent
Excessive vibration
Bent or damaged cutter
Replace cutter
Heavy sparking occurs inside motor
housing
Brushes not moving freely
Disconnect power, remove brushes, clean or replace
Armature short circuited or open circuited
Contact an authorised repair agent
Commutator dirty
Contact an authorised repair agent
Fine Adjustment Knob (14) “clicks”
or not adjusting
Plunge Lock Lever (15) engaged
Release Plunge Lock Lever
Reached end of adjustment range
Reset Fine Adjustment Knob and set depth with Depth Stop Wheel (2)
Troubleshooting
264895_MANUAL.indd 8
01/06/2017 16:07