AN332
Confidential Rev. 0.2
15
Command 0x13. GET
_
PROPERTY
Gets a property shown in Table 5, “FM Transmitter Property Summary,” on page 7. The CTS bit (and optional
interrupt) is set when it is safe to send the next command. This command may only be sent when in powerup
mode.
Command arguments: Three
Response bytes: Three
Command
Response
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
0
0
1
0
0
1
1
ARG1
0
0
0
0
0
0
0
0
ARG2
PROP
H
[7:0]
ARG3
PROP
L
[7:0]
ARG
Bit
Name
Function
1
7:0
Reserved
Always write to 0.
2
7:0
PROP
H
[7:0]
Property Get High Byte.
This byte in combination with PROP
L
is used to specify the property to get.
3
7:0
PROP
L
[7:0]
Property Get Low Byte.
This byte in combination with PROP
H
is used to specify the property to get.
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
X
RDSINT
ASQINT
STCINT
RESP1
X
X
X
X
X
X
X
X
RESP2
PROPD
H
[7:0]
RESP3
PROPD
L
[7:0]
RESP
Bit
Name
Function
1
7:0
Reserved
Reserved, various values.
2
7:0
PROPD
H
[7:0]
Property Value High Byte.
This byte in combination with PROPV
L
will represent the requested prop-
erty value.
3
7:0
PROPD
L
[7:0]
Property Value High Byte.
This byte in combination with PROPV
H
will represent the requested prop-
erty value.