AN332
130
Confidential Rev. 0.2
Property 0x3400. AM_SEEK_BAND_BOTTOM
Sets the lower boundary for the AM band in kHz. This value is used to determine when the lower end of the AM
band is reached when performing a seek. The CTS bit (and optional interrupt) is set when it is safe to send the next
command. This property may only be set or read when in powerup mode. The default is 520 kHz (0x0208).
Default: 0x0208
Units: kHz
Step: 1 kHz
Valid Range: 149–23000 kHz
Recommended Range:
AM in US:
520–1710 kHz
AM in Asia:
522–1710 kHz
SW:
2300–23000 kHz
LW:
153–279 kHz
Bit
D15 D14 D13 D12 D11 D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Name
AMSKFREQL[15:0]
Bit
Name
Function
15:0
AMSKFREQL
AM Seek Band Bottom.
Specify the lower boundary of the AM band when performing a seek. The seek either
stops at this limit or wraps based on the parameters of AM_SEEK_START command
that was issued to initiate a seek. The default value for the lower boundary of the AM
band is 520 kHz.