AN332
Confidential Rev. 0.2
13
Command 0x11. POWER
_
DOWN
Moves the device from powerup to powerdown mode. The CTS bit (and optional interrupt) is set when it is safe to
send the next command. This command may only be sent when in powerup mode. Note that only the POWER_UP
command is accepted in powerdown mode.
If the system controller writes a command other than POWER_UP
when in powerdown mode, the device does not respond. The device will only respond when a POWER_UP
command is written.
Note:
In FMTX component 1.0 and 2.0, a reset is required when the system controller writes a command other than
POWER_UP when in powerdown mode.
Command arguments: None
Response bytes: None
Command
Response
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
0
0
1
0
0
0
1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
X
RDSINT
ASQINT
STCINT