AN332
Confidential Rev. 0.2
49
Property 0x2C04. TX_RDS_PS_REPEAT_COUNT (Si4711/13/21 Only)
Sets the number of times a program service group 0A is repeated. The CTS bit (and optional interrupt) is set when
it is safe to send the next command. This property may only be set or read when in powerup mode.
Note:
TX_RDS_PS_REPEAT_COUNT is supported in FMTX component 2.0 or higher.
Default: 0x0003
Range: 1–255
Property 0x2C05. TX_RDS_PS_MESSAGE_COUNT (Si4711/13/21 Only)
Sets the number of program service messages through which to cycle. The CTS bit (and optional interrupt) is set
when it is safe to send the next command. This property may only be set or read when in powerup mode.
Note:
TX_RDS_PS_MESSAGE_COUNT is supported in FMTX component 2.0 or higher.
Default: 0x0001
Range 1–12
Bit
D15 D14 D13 D12 D11 D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
0
0
0
0
0
RDSPSRC[7:0]
Bit
Name
Function
15:8
Reserved
Always write to 0.
7:0
RDSPSRC[7:0]
Transmit RDS PS Repeat Count.
Number of times to repeat transmission of a PS message before transmitting the
next PS message.
Bit
D15 D14 D13 D12 D11 D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
0
0
0
0
0
0
0
0
0
RDSPSMC[3:0]
Bit
Name
Function
15:4
Reserved
Always write to 0.
3:0
RDSPSMC[3:0]
Transmit RDS PS Message Count.
Number of PS messages to cycle through. Default is 1.