AN332
222
Confidential Rev. 0.2
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x12
0x02
0x00
0x06
→
0x80
SET_PROPERTY
FM_RSQ_SNR_LO_THRESHOLD
Threshold = 6 dB = 0x0006
Reply Status. Clear-to-send high.
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x12
0x03
0x00
0x32
→
0x80
SET_PROPERTY
FM_RSQ_RSSI_HI_THRESHOLD
Threshold = 50 dBµV = 0x0032
Reply Status. Clear-to-send high.
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x12
0x04
0x00
0x18
→
0x80
SET_PROPERTY
FM_RSQ_RSSI_LO_THRESHOLD
Threshold = 24 dBµV = 0x0018
Reply Status. Clear-to-send high.
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x12
0x07
0x00
0xB2
→
0x80
SET_PROPERTY
FM_RSQ_BLEND_THRESHOLD
Pilot = 1, Threshold = 50% = 0x0032
Reply Status. Clear-to-send high.
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x13
0x02
0x00
0x0A
→
0x80
SET_PROPERTY
FM_SOFT_MUTE_MAX_ATTENUATION
Attenuation = 10 dB = 0x000A
Reply Status. Clear-to-send high.
Table 47. Programming Example for the FM/RDS Receiver (Continued)
Action
Data
Description