5.4.1. WB Receiver Commands
Command 0x01. POWER_UP
Initiates the boot process to move the device from powerdown to powerup mode. The boot can occur from internal
device memory or a system controller downloaded patch. To confirm that the patch is compatible with the internal
device library revision, the library revision should be confirmed by issuing the POWER_UP command with FUNC =
15 (query library ID). The device returns the response, including the library revision, and then moves into
powerdown mode. The device can then be placed in powerup mode by issuing the POWER_UP command with
FUNC = 3 (WB Receive) and the patch may be applied (See Section “7.2 Powerup from a Component Patch” on
page xx).
The POWER_UP command configures the state of ROUT (pin 13), LOUT (pin 14) for analog audio mode. The
command configures GPO2/INT~ interrupts (GPO2OEN) and CTS interrupts (CTSIEN). If both are enabled,
GPO2/IRQ is driven high during normal operation and low for a minimum of 1
μ
s during the interrupt. The CTSIEN
bit is duplicated in the GPO_IEN property. The command is complete when the CTS bit (and optional interrupt) is
set.
To change function (e.g., WB RX to FM RX), issue POWER_DOWN command to stop current function; then, issue
POWER_UP to start new function
Command Arguments: Two
Response Bytes: None (FUNC=3), Seven (FUNC=15)
Command
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
0
0
0
0
0
0
1
ARG1
CTSIEN
GPO2OEN
PATCH
XOSCEN
FUNC[3:0]
ARG2
OPMODE[7:0]