AN332
Confidential Rev. 0.2
143
Command 0x11. POWER_DOWN
Moves the device form powerup to powerdown mode. The CTS bit (and optional interrupt) is set when it is safe to
send the next command. This command may only be sent when in powerup mode. Note that only the POWER_UP
command is accepted in powerdown mode.
If the system controller writes a command other than POWER_UP
when in powerdown mode, the device does not respond. The device will only respond when a POWER_UP
command is written.
Command arguments: None
Response bytes: None
Command
Response
Command 0x12. SET_PROPERTY
Sets a property shown in Table 17, “WB Receive Property Summary,” on page 137. The CTS bit (and optional
interrupt) is set when it is safe to send the next command. This command may only be sent when in powerup
mode.
Command Arguments: Five
Response bytes: None
Command
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
0
0
1
0
0
0
1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
STATUS
CTS
ERR
X
X
RSQINT
SAMEINT
ASQINT
STCINT
Bit
D7
D6
D5
D4
D3
D2
D1
D0
CMD
0
0
0
1
0
0
1
0
ARG1
0
0
0
0
0
0
0
0
ARG2
PROP
H
[7:0]
ARG3
PROP
L
[7:0]
ARG4
PROPV
H
[7:0]
ARG5
PROPV
L
[7:0]