Property 0x1100. FM_DEEMPHASIS (Not applicable for Si4749)
Sets the FM Receive de-emphasis to 50 or 75 µs. The CTS bit (and optional interrupt) is set when it is safe to send
the next command. This property may only be set or read when in powerup mode. The default is 75 µs.
Default: 0x0002
Property 0x1102. FM_CHANNEL_FILTER (Si4706/49 Only)
Selects bandwidth of channel filter applied at the demodulation stage. Default is automatic which means the device
automatically selects proper channel filter. The CTS bit (and optional interrupt) is set when it is safe to send the
next command. This property may only be set or read when in powerup mode. The default is 1.
Default: 0x0001
Range: 0–4
Bit
D15 D14 D13 D12 D11 D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
0
0
0
0
0
0
0
0
0
0
0
DEEMPH[1:0]
Bit
Name
Function
15:2
Reserved
Always write to 0.
1:0
DEEMPH[1:0]
FM De-Emphasis.
10 = 75 µs. Used in USA (default)
01 = 50 µs. Used in Europe, Australia, Japan
00 = Reserved
11 = Reserved
Bit
D15 D14 D13 D12 D11 D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Name
FMCHFILT[15:0]
Bit
Name
Function
15:0
FM_CHANNEL_FILTER
0 = Automatically select proper channel filter.
1 = Force wide (110 kHz) channel filter.
2 = Force narrow (84 kHz) channel filter.
3 = Force narrower (60 kHz) channel filter.