![Silicon Laboratories Si4700 Programming Manual Download Page 205](http://html.mh-extra.com/html/silicon-laboratories/si4700/si4700_programming-manual_1271960205.webp)
AN332
Confidential Rev. 0.2
205
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x22
0x00
0x00
0x03
→
0x80
SET_PROPERTY
TX_ACOMP_ENABLE
Enable the limiter and compressor.
Reply Status. Clear-to-send high.
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x22
0x05
0x00
0x0D
→
0x80
SET_PROPERTY
TX_LIMITER_RELEASE_TIME
Sets the limiter release time to 13 (39.38 ms)
Reply Status. Clear-to-send high.
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x23
0x01
0x00
0xCE
→
0x80
SET_PROPERTY
TX_ASQ_LOW_LEVEL
–50 dB = 0x00CE
Reply Status. Clear-to-send high.
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x23
0x02
0x27
0x10
→
0x80
SET_PROPERTY
TX_ASQ_DURATION_LOW
10000 ms = 0x2710
Reply Status. Clear-to-send high.
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x23
0x03
0x00
0xEC
→
0x80
SET_PROPERTY
TX_ASQ_HIGH_LEVEL
–20 dB = 0x00EC
Reply Status. Clear-to-send high.
CMD
ARG1
ARG2 (PROP)
ARG3 (PROP)
ARG4 (PROPD)
ARG5 (PROPD)
STATUS
0x12
0x00
0x23
0x04
0x13
0x88
→
0x80
SET_PROPERTY
TX_ASQ_DURATION_HIGH
5000 ms = 0x1388
Reply Status. Clear-to-send high.
Table 46. Programming Example for the FM/RDS Transmitter (Continued)
Action
Data
Description