Property 0x3403. AM_SEEK_TUNE_SNR_THRESHOLD
Sets the SNR threshold for a valid AM Seek/Tune. If the value is zero, then SNR is not used as a valid criteria when
doing a seek for AM. The CTS bit (and optional interrupt) is set when it is safe to send the next command. This
property may only be set or read when in powerup mode. The default threshold is 5 dB.
Default: 0x0005
Units: dB
Step: 1
Range: 0–63
Bit
D15
D14 D13 D12 D11 D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
0
0
0
0
0
0
0
AMSKSNR[5:0]
Bit
Name
Function
15:6
Reserved
Always write to 0.
5:0
AMSKSNR
AM Seek/Tune SNR Threshold.
SNR Threshold which determines if a valid channel has been found during Seek/Tune.