EM358x
Rev. 0.4
85
SCx_SPISTAT
SC1_SPISTAT
SPI Status Register
Address: 0x4000C840 Reset: 0x0
SC2_SPISTAT
SPI Status Register
Address: 0x4000C040 Reset: 0x0
31
30
29
28
27
26
25
24
0
0
0
0
0
0
0
0
23
22
21
20
19
18
17
16
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
SC_SPITXIDLE SC_SPITXFREE SC_SPIRXVAL SC_SPIRXOVF
Bitname
Bitfield
Access Description
SC_SPITXIDLE
[3]
R
This bit is set when both the transmit FIFO and the transmit serializer are
empty.
SC_SPITXFREE
[2]
R
This bit is set when the transmit FIFO has space to accept at least one
byte.
SC_SPIRXVAL
[1]
R
This bit is set when the receive FIFO contains at least one byte.
SC_SPIRXOVF
[0]
R
This bit is set if a byte is received when the receive FIFO is full. This bit is
cleared by reading the data register.