UNOCODE PRO
Operating manual - English
68
Copyright Silca 2017
6.13.2
ERROR MESSAGES
• This message appears when the cutter is unable to identify the keys measurements when cutting by means of
electric contact.
• During the reading or decoding cycle the machine’s optical reader verified that the key gauge had not been
lowered.
• The automatic setting revealed a variation that exceeded the permitted nominal figure setting reference. Carefully
repeat the setting procedure.
• During the setting of the “machine’s zero points” there is a contact failure between the two templates (see
Ch.6.10.8, page 55).
• This message indicates that during the reading cycle an anomalous form has been revealed that cannot be
reproduced with the cutters provided.
• The Machine ID has not been set. In such cases access cannot be gained to Protected Systems until the
Machine ID is set. Select menu 6.12 "ENABLING"and check that the Machine ID is different from 0. To set
Machine ID ask for a Software update valid for your machine and install with the SILCA WinTransfer Program or
SILCA Code Program.
ERROR 1
Key not
properly installed!
ERROR 2
key gauge out
of place!
ERROR 3
Exceeded setting
tolerance limit
See operating manual
ERROR 4
No template
contact made.
See operating manual
ERROR 5
Key cannot be
copied
ERROR 6
Machine ID
not defined
See operating manual