Operating manual - English
UNOCODE PRO
Copyright Silca 2017
29
Modify cutting method
• By pressing F1 it is possible to view the cutting method set by Silca for the card and to modify it when possible
(Ch.6.5.1, page 34).
Note: the editing can be saved as User Parameters.
Use of Electric Contact
• Press F2 to enable or disable the electrical contact function to read the key blank measurements.
The symbol (*) in the clamp field means that the key will be cut reading the key blank
measurements by electrical contact.
A red “X” on the electrical contact icon means that it has been disabled.
Note: some cutting cards do not include electrical contact. In such cases the software does not allow
editing.
Note: the editing can be saved as User Parameters.
• Press F3 to vary the setting for the value of the key blank measurements.
Note: when electrical contact is used it is advisable to set key blank measurements that are the same
as those of the key to be cut.
F1
F2
F3