Operating manual - English
UNOCODE PRO
Copyright Silca 2017
51
6.9.2
CALIBRATE CUTTERS
From the Gauging menu press F2 to enable the cutter gauging
function.
GREEN:
the cutter has not yet reached its limit (max number
of keys to be cut) set and enabled on the next screen.
RED: the set limit has been reached; in this case it is advis-
able to replace the “worn” cutter with a new one.
When the worn cutter is replaced press “F1” to confirm replacement.
The set User Limit remains active and the counter starts again.
The User Limit (optional) is user definable and indicates the
maximum number of keys to be cut (at user’s discretion) with
the selected cutter.
With the up/down arrow keys select the U01W standard cutter
and press ENTER.
The display will show:
• The positive or negative values are obtained by pressing F1
(+) or F2 (-).
• Press F3 to cancel the adjustments made.
Adjustments can be made within a range b30 and –30 hundredths of a mm.
The “Automatic cutter calibration” function is used to gauge the
optional cutters.
ATTENTION: automatic calibration is not available for the
U01W cutter.
• If the original Silca U01W cutter is replaced with another Silca
original, there is no need to repeat clamp gauging.
• If the original Silca U01W cutter is replaced with one that is
NOT original or has been sharpened, it will be necessary to
repeat clamp gauging and also gauge all the optional cutters.
F2
F1
F2
F3