Press ENTER, the display will show:
-
Fit the test key blank (Z3 template) into side A of the left-hand clamp
(Stop 0).
Fig. 27
-
Lower the safety shield and press START. When cutting is complete
the display will show:
-
Fit the test key (Z3 template) cut and carefully cleaned into side A of
the right-hand clamp (Stop 0).
Fig. 28
-
Lower the safety shield and press START. When reading is complete
the display will show:
-
Raise the safety shield, remove the Z3 template from the right-hand
clamp and replace with a carefully cleaned Z20 template (Stop 0).
Fig. 29
-
Lower the safety shield and press START.
-
After an intermediate message “Reading template measurements”
the display will show:
• Press ENTER to confirm the data.
• Press STOP to exit without confirming.
Note: acceptable value range: +/- 40 hundredths of a
millimetre.
Press ENTER, the display will show:
Z3