CALIBRATE ADAPTERS
From the Gauging menu press F3 to enable the Adapter gauging
function.
Use the up/down arrow keys to select the adapter to be gauged
and press ENTER.
The display will show:
• Use the “right or left” arrow keys to change the adjustment
field (X or Y).
• Positive or negative values are obtained by pressing F1 (+)
or F2 (-).
• Press F3 to cancel the adjustments made.
Adjustments can be made within a range b30 and -30
hundredths of a mm.