Operating Manual - English
Triax QUATTRO
Copyright Silca 2011
- 57 -
5.11.8
MACHINE ZEROS
The machine is prepared with a “self-calibration” system which uses a template (provided) and special
procedures.
THE MACHINE ZEROS PROCEDURE MUST BE CARRIED OUT ONLY WHEN THE FOLLOWING EVENTS OCCUR:
EVENT
MACHINE ZEROS
CLAMP
calibration
TRACER TOWER
calibration
Photocell replacement
YES YES
NO
Electronic circuit board replacement
YES YES
YES
Sensor replacement
NO YES
NO
Ball screw replacement
YES YES
NO
Tracer Tower decoder replacement or maintenance
NO NO
YES
PRELIMINARY
OPERATIONS
1.
Switch off the machine and disconnect from mains.
2.
Remove back plate.
3.
Loosen the grub screws securing the photocell disk for Y (G) and Z (L) axes.
4.
Remove bottom plate.
5.
Remove the X axis carriage cover by loosening the 3 screws (B5) and pull out in the direction given, then
remove the belt cover.
6.
Loosen the grub screws securing the X axis photocell disk.
7.
Reconnect the power lead.
8.
Switch on the machine and follow the procedure described below.
N.B.
the operation to load "machine zeros" must be carried out by following the instructions below.
After this operation keys cannot be cut or decoded because the machine program will require all clamps
to be re-calibrated!
PROCEDURE
Select
Machine zeros
and press ENTER.
Remove the clamp from its support and fit the template (Z5 – wording
towards operator) all the way into the dovetail guide and secure by
tightening the grub screw.
Press ENTER.
Summary of Contents for Triax Quattro
Page 2: ......
Page 4: ......
Page 8: ......
Page 106: ...Triax QUATTRO Copyright Silca 2011 1 II ...
Page 107: ...Triax QUATTRO Copyright Silca 2011 III ...
Page 108: ...Triax QUATTRO Copyright Silca 2011 1 IV ...
Page 109: ...Triax QUATTRO Copyright Silca 2011 V ...
Page 110: ...Triax QUATTRO Copyright Silca 2011 1 VI ...
Page 111: ...Triax QUATTRO Copyright Silca 2011 VII ...
Page 112: ...Triax QUATTRO Copyright Silca 2011 1 VIII ...
Page 113: ...Triax QUATTRO Copyright Silca 2011 IX ...