Parameters
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 29 of 79
Name
Description
see page
Menu lock code
Time period, during which the button
must be pressed to start
parameterization.
Key to trigger calibration
Key to trigger increment
Key to trigger configuration
0018h: Key Acknowledgment Mode
Key to trigger acknowledgment
Number of decimal places
Display divisor ADI
Display of the direction indicators
Display orientation
Resolution
Counting direction
The offset value is added to the position
value in the encoder.
The calibration value is set during
calibration.
Direction in which the target value is
approached.
Loop length (clearance compensation)
If the actual value lies within the target
window, the target value is reached.
Extended target window for better
positioning at high travel speed.
0034h: Target Window Extended
Visualization
Visualization of extended target window
Operating mode
Display factor
Display mode operation
Data content line 1 with active display
string mode
Data content line 2 with active display
string mode
003Ch: Sensor Type
Sensor type (MS500H, GS04)
003Fh: Displayed Value 2nd Line
Controls the display of the 2nd line of
the display
Application of the display divisor ADI
Formation of the differential value
Flashing of all LEDs
LED1 green mode
LED1 red mode
LED2 green mode
LED2 red mode