Parameters
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 55 of 79
Display
Menu
K CAL
(
chPARA
\
OPTION
\
K CAL
)
Data type Unsigned8
Value range
0 … 1
Default
1 (default)
Parameter selection
Value
Display
Description
0
DISABL
Blocked
1
ENABLE
Release
4.5.15
Key Incremental
This parameter specifies whether the setting of the position value is enabled by pressing a
key.
General characteristics
EEPROM
yes
Class
V
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0021d / 15h
Web server
21
Display
Menu
K INC
(
chPARA
\
OPTION
\
K INC
)
Data type Unsigned8
Value range
0 … 1
Default
1 (default)
Parameter selection
Value
Display
Description
0
DISABL
Blocked
1
ENABLE
Released
4.5.16
Key Acknowledgment Mode
This parameter can be used to specify which key is to be used as an acknowledgment key.
The setting is only relevant in the
alphanumeric display
mode. In this case, a received target
value is displayed flashing until its reception is acknowledged by the pressing of a button.