Parameters
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 53 of 79
General characteristics
EEPROM
yes
Class
V
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0066d / 42h
Web server
66
Display
Menu
DDIVMD
(
chPARA
\
OPTION
\
DDIVMD
)
Data type Unsigned8
Value range
0 … 2
Default
0 (default)
Parameter selection
Value
Display
Description
0
ALL
Display, target value and interface output are
calculated with the divisor.
1
DI+TAR
Display and target value are calculated with
the divisor.
2
DISPL
Display is calculated with the divisor.
4.5.12
Key Enable Time
This parameter sets the delay of the display of the parameter menu (release time buttons).
General characteristics
EEPROM
yes
Class
V
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0019d / 13h
Web server
19
Display
Menu
K TIME
(
chPARA
\
OPTION
\
K TIME
)