Parameters
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 32 of 79
Value
Display
Description
3
0003
0.003
4
00004
0.0004
4.2.3
Counting Direction
General characteristics
EEPROM
yes
Class
S
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0030d / 1Eh
Web server
30
Display
Menu
CntDIR
(
chPARA
\
POSI
\
CntDIR
)
Data type Unsigned8
Value range
0 … 1
Default
0 (default)
Parameter selection GS04
Value
Display
Description
0
CW
clockwise
1
CCW
counter-clockwise
CW counting direction:
ascending position values with clockwise shaft rotation (CW, view on
the display).
CCW counting direction:
ascending position values with counter-clockwise shaft rotation
(CCW, view on the display).
Parameter selection MS500H
Value
Display
Description
0
POS
in positive direction of travel
1
NEG
in negative direction of travel
POS counting direction:
ascending position values with corresponding change of the sensor
position in the positive direction.
NEG counting direction:
descending position values with a corresponding change in the
sensor position in the positive direction.
The positive sensor orientation depends on the mounting type of the sensor. Observe the
corresponding installation instructions of the sensor in this regard.