Parameters
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 50 of 79
Display
Menu
Data type Integer32
Value range
-5242880 … 5242880
Default
0 (default)
4.5.8
Difference Value Mode
General characteristics
EEPROM
yes
Class
V
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0067d / 43h
Web server
67
Display
Menu
DIFFMD
(
chPARA
\
VISUAL
\
DIFFMD
)
Data type Unsigned8
Value range
0 … 1
Default
0 (default)
Parameter selection
Value
Display
Description
0
POS-TA
DIFF = Actual - Target
1
TA-POS
DIFF = Target - Actual
4.5.9
Display Factor
If a display factor>0 is set, all values on the display are indicated in inch.
It should be noted that the transmission values from and to the interface are present in the
metric system (depending on resolution and ADI). The control delivers target, calibration and
offset values as well as loop length and target window metrically as well. Device-internal
position monitoring is metrical. Therefore, the superordinate control can only function in the
metric system. The values for position, target value and the differential value if applicable are
calculated by means of the following formula (for position value):
Display value
=
position value
x
calculation factor
Calculation factor
=
1
0.254
x 10
4-Display factor