Functional Description
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 26 of 79
3.7.3
Restore factory settings
There are various options for restoring the factory settings of the device:
Access
Coding
Factory settings are restored
Manual
CODE
(chapter
11100
all parameters
11102
all except bus parameters
11105
only bus parameters
Load
Default
All
all parameters
StAnd
all except bus parameters (standard)
NETWRK
only bus parameters
Interface
(Parameter System
Command
see chapter
FFh
1
all parameters
2
all except bus parameters
3
only bus parameters
Table 17: Access to factory settings
3.8
Warnings / Errors
3.8.1
Warnings
Warnings do not influence the acquisition of the absolute actual value.
Warnings are deleted after removing the cause.
Possible warnings:
Battery voltage for absolute position detection is below limit
immediately exchange
battery!
This warning is displayed with a blinking battery symbol
. Warning messages are
output via the interface via the status word.
Display
Bit assignment in the status word Error
flashing Bit 11
Low battery voltage (critical)
Actual value is still valid!
Table 18: Warnings
3.8.2
Errors
Calibration may also be required Depending on the error type.
Error states are signaled via display (written in red or battery symbol) and interface.
To return to normal operation, the cause must be removed. Error signaling (display flashes
red) can then be acknowledged or deleted with the button or via the interface.
If calibration is required, this is indicated in the display as "
CALIB REQUEST
".
Independent of acknowledgment of the error status.