Parameters
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 35 of 79
Data type Unsigned16
Value range
0 … 9999
Default
0 (default)
4.2.8
Loop Type
This parameter specifies the positioning type, the loop type. This selects the direction in
which the target value is to be approached.
General characteristics
EEPROM
yes
Class
S
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0048d / 30h
Web server
48
Display
Menu
LOOP
(
chPARA
\
POSI
\
LOOP
)
Data type Unsigned8
Value range
0 … 2
Default
0 (default)
Parameter selection GS04
Value
Display
Description
0
DIR
direct, no loop
1
CW
clockwise
2
CCW
counter-clockwise
Parameter selection MS500H
Value
Display
Description
0
DIR
direct, no loop
1
POS
Positive travel loop
2
NEG
Negative travel loop
The positive sensor orientation depends on the mounting type of the sensor. Observe the