Parameters
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 54 of 79
Data type Unsigned8
Value range
1 … 60
Default
5 (default)
4.5.13
Key Configuration
With this parameter, the parameterization is enabled at pressing of a key.
If the configuration is locked, a CODE query is displayed instead to be able to unlock a locked
position display manually (see chapter
General characteristics
EEPROM
yes
Class
V
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0022d / 16h
Web server
22
Display
Menu
Data type Unsigned8
Value range
0 … 1
Default
1 (default)
4.5.14
Key Calibration
This parameter specifies whether the calibration of the position value is enabled by pressing a
key.
General characteristics
EEPROM
yes
Class
V
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0020d / 14h
Web server
20