Parameters
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 33 of 79
4.2.4
Calibration Value
The current calibration value is always displayed in the ReadOnly menu (see chapter
); it
is always replaced with the parameter value only after an executed calibration.
To perform a calibration, the system command "Calibration" must be executed
(see chapter
General characteristics
EEPROM
yes
Class
S
Unit
-
PROFINET
Data type
Integer32
Access
Get/Set
Instance
0046d / 2Eh
Web server
46
Display
Menu
CALVAL
(
chPARA
\
POSI
\
CALVAL
)
Data type Integer32
Value range
-999999 … 999999
Default
0 (default)
4.2.5
Offset Application
This parameter sets the offset value.
With the offset, it is possible to move the scaled value range. The offset value is added to the
position value in the encoder. Both positive and negative values are permitted. Position value
= measurement value + calibration value.
General characteristics
EEPROM
yes
Class
S
Unit
-
PROFINET
Data type
Integer16
Access
Get/Set
Instance
0045d / 2Dh
Web server
45
Display
Menu
OFFSET
(
chPARA
\
POSI
\
OFFSET
)