Parameters
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 52 of 79
4.5.10
Display Divisor
General characteristics
EEPROM
yes
Class
V
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0026d / 1Ah
Web server
26
Display
Menu
DISDIV
(
chPARA
\
POSI
\
DISDIV
)
Data type Unsigned8
Value range
0 … 3
Default
0 (default)
Parameter selection
Value
Display
Description
0
1
1
1
10
10
2
100
100
3
1000
1000
Examples:
(Application of the Display Divisor see chapter
Position value
ascertained
DISDIV
(12h)
DISDIVMOD-
application
(25h)
Display
Output
interface
Target value
received
Target
attained
12348
2
0
123
123
123
yes
12348
2
1
123
12348
123
yes
12348
2
1
123
12348
12348
no
12348
1
2
1235
12348
12348
yes
12348
1
2
1235
12348
1235
no
12348
3
2
12
12348
12348
yes
12348
3
2
12
12348
1235
no
Table 23: ADI and ADI application
4.5.11
Display Divisor Mode
This parameter can be used to set the application of the display divisor for the determined
position values (absolute position value, frozen position value) as well as the received target
value (display divisor and examples see chapter