MapIT G2 Hardware Installation Training Manual
Confidential – June 2014
37
If no patch cable is connected to the port, only one line of information is displayed
showing the panel/port information.
If a port is probed and no information appears, begin troubleshooting sequence
described later in this document.
Port Diagnostics information is also displayed on the Smart Patch Panels and Fiber
Enclosures. Once the port is probed, the port number and panel ID will display on the
panel LCD. The green LED will also illuminate to help identify the panel(s).
The screens will show the port icon and port number on the first line and a panel icon
and panel ID on the second line. The LCD screens will then alternate between
showing this information for the connected panels. An example is shown below:
If no Patch Cable is present, only the LCD and LED on the probed panel will illuminate
and display the port and panel information.
If a port is probed and the LCD/LED does not illuminate and doesn’t display any
information, begin the troubleshooting procedure described later in this document.
This information will continue to display until one of the following events occurs:
1. You press the
prev
button
2. The components times out (see component time out in the Settings section)
To conduct port diagnostics on another port, hit the
prev
button and probe the next
port.