![Siemens SIWAREX WP251 Manual Download Page 191](http://html.mh-extra.com/html/siemens/siwarex-wp251/siwarex-wp251_manual_374538191.webp)
Communication with SIMATIC S7-1200
11.1 Integration in SIMATIC S7-1200
SIWAREX WP251
Manual, 12/2015, A5E37203357A
191
11.1.5
I/O interface of function block
The instance data block of the function block provides the "s_IO_DATA" structure. All
parameters in this structure are updated cyclically by WP251 to SIMATIC. Thus, all values
within the structure can be used directly – without reading or writing data records! The
following parameters are available for use within "s_IO_DATA" on the factory side.
Image 11-7 s_IO_DATA
Parameter (read)
Meaning
AWI Status
AWI Status bits according to data record 30
PROCESS_VAL_1
Process value according to setting in data record 14 in REAL format (default=gross/net weight)
PROCESS_VAL_2
Process value according to setting in data record 14 in REAL format (default=NAWI Status bits
according to data record 30)
dw_PROCESS_VAL_1
Process value according to setting in data record 14 in DWORD format (default=gross/net
weight)
dw_PROCESS_VAL_2
Process value according to setting in data record 14 in DWORD format (default=NAWI Status
bits according to data record 30)
AWI Status
AWI Status bits according to data record 30
OPERATION_ERRORS
Operating errors according to the "Messages" section
Summary of Contents for SIWAREX WP251
Page 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Page 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Page 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...