8.12.5
Subnet mask
Assign the subnet mask of your network.
8.12.6
Gateway
If a gateway is used between the SIWAREX WP251 and the communication partner, enter
the gateway address here.
If a gateway is not present, enter the IP address of the SIWAREX module.
8.12.7
Device name
This parameter can be used to assign a name to the weighing module in the Ethernet
network. The length of the name is limited to 32 characters. Empty spaces must be filled by
"x".
8.13
DR 13 RS485 parameters
8.13.1
Overview
The parameter assignment of the RS485 interface occurs in data record DR 13. If the
interface is not used, the default values can be retained.
Table 8- 12 Assignment of data record 13
Variable
Note
Type
Length
(bytes)
Rw
Default Min.
Max.
Modbus
registers
Data record
number
Contains no. of the data
record
USHORT
2
r
13
-
-
1558
Length
Data record length infor-
mation
USHORT
2
r
24
-
-
1559
Application
Information about which
application the data record
belongs to
USHORT
2
r
105
-
-
1560
Version
identifier
Current data record version
information
USHORT
2
r
1
1
65635
1561
(Page 102)
0: No protocol
1: MODBUS RTU
2: SIEBERT display
USHORT 2
rw
1
0
2
1562