![Siemens SIWAREX WP251 Manual Download Page 147](http://html.mh-extra.com/html/siemens/siwarex-wp251/siwarex-wp251_manual_374538147.webp)
Scale parameters and functions
8.29 DR 32 Error messages
SIWAREX WP251
Manual, 12/2015, A5E37203357A
147
Variable
Note
Type
Length
(bytes)
RW De-
fault
Mi
n.
Max. Mod-
bus
regis-
ters
2003 Initial zero setting on
not possible
The weight at switch-on is outside
the permissible initial zeroing
range
Bit_3
0
r
0
-
-
3505
2004 Trace memory full
Cyclic trace recording aborted
because memory is full
Bit_4
0
r
0
-
-
3505
Reserve
Reserve
Bit_5
0
r
0
-
-
3505
Reserve
Reserve
Bit_6
0
r
0
-
-
3505
Reserve
Reserve
Bit_7
1
r
0
-
-
3505
2101 Risk of overfilling
Current configuration would lead
to overfilling during dosing
Bit_8
0
r
0
-
-
3505
2102 Coarse shut-off point
already exceeded
The coarse shut-off point is al-
ready exceeded before switching
on the coarse signal
Bit_9
0
r
0
-
-
3505
2103 No standstill
Required standstill did not occur
during the dosing operation
Bit_10
0
r
0
-
-
3505
2104 CPU in "STOP"
No stand-alone operation activat-
ed and no CPU or CPU is in
"STOP" state
Bit_11
0
r
0
-
-
3505
2105 Set point too small
The set point for the dosing is too
small in the current configuration
Bit_12
0
r
0
-
-
3505
2106 Error fine weight
Trailing weight, shut-off correction
value and set point are not com-
patible
Bit_13
0
r
0
-
-
3505
2107 Stop after tolerance
error
Weighing cycle stopped after
tolerance error based on parame-
ter assignment
Bit_14
0
r
0
-
-
3505
Reserve
Reserve
Bit_15
1
r
0
-
-
3505
2109 Blocking time
"coarse" error
Blocking time coarse signal After
expiration of the blocking time
coarse signal, the coarse shut-off
point was already exceeded.
Bit_0
0
0
-
-
3506
2110 Blocking time "fine"
error
Blocking time fine signal violation
After expiration of the blocking
time fine signal, the fine shut-off
point was already exceeded.
Bit_1
0
r
0
-
-
3506
2111 Maximum weighing
time exceeded
Maximum dosing time was ex-
ceeded
Bit_2
0
r
0
-
-
3506
2112 Logging not possible -
no standstill
Logging conditions are not met,
automatic logging cannot be per-
formed
Bit_3
0
r
0
-
-
3506
2113 Maximum emptying
time exceeded
Emptying monitoring time expired Bit_4
0
r
0
-
-
3506
2114 Maximum corrective
action exceeded
Maximum corrective action was
exceeded
Bit_5
0
r
0
-
-
3506
2115 Log error
Error while reading a log entry
Bit_6