![Siemens SIWAREX WP251 Manual Download Page 182](http://html.mh-extra.com/html/siemens/siwarex-wp251/siwarex-wp251_manual_374538182.webp)
Command lists
10.2 Command lists
SIWAREX WP251
182
Manual, 12/2015, A5E37203357A
Command
code
Command
Description
Protected
722
Display total set point
Display currently total set point setting from DR 21 on
the main display (DR 34) and the SecureDisplay for 5
seconds.
771
Display Totalizer 1
Display Totalizer 1 from DR 30
772
Display Totalizer 2
Display Totalizer 2 from DR 30
801
Display Current Restriction Code
Display restriction code set in DR 3 on the main dis-
play (DR 34) and the SecureDisplay for 5 seconds
(command only relevant for scales requiring official
calibration).
802
Display weighing range data
Show weighing range data (Min, Max, Resolution) in
SecureDisplay for 10 seconds (command only rele-
vant for scales requiring official calibration).
860
Hide SecureDisplay
Places SecureDisplay in the background of the HMI
(command only relevant for scales requiring official
calibration).
861
SecureDisplay position 1
Shows the SecureDisplay on the HMI in position 1
(see DisplayCali.xml).
862
SecureDisplay position 2
Shows the SecureDisplay on the HMI in position 2
(see DisplayCali.xml).
863
SecureDisplay position 3
Shows the SecureDisplay on the HMI in position 3
(see DisplayCali.xml).
864
SecureDisplay position 4
Shows the SecureDisplay on the HMI in position 4
(see DisplayCali.xml).
865
SecureDisplay position 5
Shows the SecureDisplay on the HMI in position 5
(see DisplayCali.xml).
870
Smallest SecureDisplay
Shows the SecureDisplay on the HMI with the small-
est zoom factor (see DisplayCali.xml).
871
Display serial number
Display serial number of SIWAREX WP251 in the
main display and the SecureDisplay for 5 seconds.
875
Display Firmware Version
Display firmware version and checksums of
SIWAREX WP251 in the main display (serial number
only) and the SecureDisplay for 5 seconds.
876
Display SecureDisplay Software
Version
Display version of SecureDisplay in the main display
and the SecureDisplay for 5 seconds.
881
Show first log book entry
Shows the first log book entry in SecureDisplay
(command only relevant for scales requiring official
calibration).
882
Display last log book entry
Shows the last log book entry in SecureDisplay
(command only relevant for scales requiring official
calibration).
883
Previous log book entry
Show the previous log book entry in SecureDisplay
(command only relevant for scales requiring official
calibration).
884
Next log book entry
Show the next log book entry in SecureDisplay
(command only relevant for scales requiring official
calibration).
891
Display protocol
Displays the last requested log in a calibratable man-
ner in SecureDisplay.