6
OPERATION
72
SITRANS FX330
www.siemens.com/flow
05/2016 - A5E36751269-AA
A11.5 Application Assistant - Gas
.15 1. Meas. Page
Same options as in A11.1.13.
.16 2. Meas. Page
Same options as in A11.1.14.
Function
Setting / Description
.1
.2 Units
Same options as in A11.1.2.
.2.1 Volume Flow
Select unit (default: according to order specification or m
3
/h).
.2.2 Norm. Vol. Flow
Select unit (default: according to order specification or Nm
3
/h).
.2.3 Mass Flow
Select unit (default: according to order specification or kg/h).
.2.4 Volume
Select unit (default: according to order specification or m
3
).
.2.5 Norm. Volume
Select unit (default: according to order specification or Nm
3
).
.2.6 Mass
Select unit (default: according to order specification or kg).
.2.7 Temperature
Select unit (default: according to order specification or
°
C).
.2.8 Pressure
Select unit (default: according to order specification or bar).
.2.9 Density
Select unit (default: according to order specification or kg/m
3
).
.3 Process
.3.1 Fluid
Select: "Gas", "Wet Gas" or "Gas Mixture".
.3.2 Medium
If fluid is "Gas" or "Wet Gas" (for details refer to
Gas options for gas measurement
on
page 56).
.3.3 Time Constant
0...100 s
.3.4 Low Flow Cutoff
Enter low flow cutoff point in current volume flow unit.
.4 Current Input
Same options as in A11.3.4.
.5.1 Temp. Source1
Internal / External / External HART / Not Available
.5.2 Temp. Source2
Internal / External / External HART / Not Available
Temperature source 1 and 2 must be different.
.6 Gas Mixture
If fluid = "Gas Mixture", enter gas mixture in %.
.7 Gas
.7.1 Relative Humidity
If fluid = "Wet Gas", enter 0
…
100%.
.8 Operating Values
Same options as in A11.1.4.
.9 Normal Values
Default settings according to order specification or DIN.
.9.1 Norm. Temperature
Confirm default setting or define in selected temperature unit.
.9.2 Norm. Pressure
Confirm default setting or define in selected pressure unit.
.9.3 Norm. Density
Confirm default setting or define in selected density unit.
.10 Current Output
Same options as in A11.1.5.
.11 Binary Output
Same options as in A11.1.6.
.12 Pulse Output
Same options as in A11.1.7.
.13 Frequency Output
Same options as in A11.1.8.
.14 Status Output
Same options as in A11.1.9.
.15 Limit Switch
Same options as in A11.1.10.
.16 Flow Totalizer
Same options as in A11.1.11.
Function
Setting / Description