8
TECHNICAL DATA
112
SITRANS FX330
www.siemens.com/flow
05/2016 - A5E36751269-AA
8.4 Flow tables
Measuring ranges
Nominal size
Q
min
Q
max
Q
min
Q
max
DN - EN 1092-1 NPS - ASME B16.5
[m
3
/h]
[gph]
Water
15
3/8
0.36
5.07
95.61
1339
25
1
0.81
11.40
215
3012
40
1
½
2.04
28.58
539
7550
50
2
3.53
49.48
934
13072
80
3
7.74
108.3
2045
28632
100
4
13.30
186.2
3514
49196
150
6
30.13
421.89
7961
111454
200
8
56.61
792.5
14954
209356
250
10
90.49
1267
23905
334681
300
12
131.4
1840
34720
486077
Values based on water at +20
°
C / +68
°
F
Air
15
3/8
4.34
32.57
1147
8605
25
1
9.77
114.0
2581
30117
40
1
½
24.50
326.6
6472
86288
50
2
42.41
565.5
11204
149390
80
3
92.90
1239
24542
327224
100
4
159.6
2128
42168
562245
150
6
361.6
4822
95532
1273761
200
8
679.3
9057
179448
2392635
250
10
1086
14478
286870
3824929
300
12
1577
21028
416638
5555167
Values based on air at +20
°
C / +68
°
F and 1.013 bara / 14.7 psia and density 1.204 kg/m
3
/ 0.0751 lb/ft
3