INSTALLATION
3
31
SITRANS FX330
www.siemens.com/flow
05/2016 - A5E36751269-AA
3.8.3 Installing devices in flange design
•
Use bolts and fastening nuts
2
to attach the measuring device to one side of the flange.
•
While doing so, insert the gaskets
1
between flow sensor and flange and align them.
•
Check that the gasket is concentric and that it is not protruding into the pipe cross-section.
•
Install the gasket, bolts and fastening nuts on the other side of the flange.
•
Align the measuring device and the gaskets so they are concentric.
•
Now tighten all nuts bit by bit alternately across the diagonal.
Figure 3-13: Installing devices in flange design
1
Sealing
2
Bolts with fastening nuts